RITG142 includes RITtrend™ – the all-in-one statistical database tracking solution, that stores data for all your department's measurements. Set your own specifications and RITtrend automatically analyzes process control limits on equipment analyzed with RIT software. The multi-source data manager gives you even more control for reporting on your entire medical physics program. RITtrend redefines database recording into a major tool for analysis and record-keeping in your department.
RITtrend™ is a trademark of Radiological Imaging Technology, Inc.
The imaging QA capabilities in RITG142 include Cerberus – the hands-free batch phantom analysis tool. Cerberus constantly operates in the background of your workstation, automatically monitoring folders and pin-pointing specific files to process and analyze. It can match many set criteria, such as file naming patterns, DICOM tag matches (up to 4 DICOM tags may be used), or file types. Cerberus automatically performs analyses, generates reports, and shares data to RITtrend, using specific parameters set in your customized preference profiles (including tolerances) to analyze the images for all of your machines.
Machine QA
Daily, Monthly, and Annual Machine QA for LINACs
- Enhanced 3D Winston-Lutz (Isocenter Optimization) with Virtual Star Shot*
Automatically process a set of EPID Winston-Lutz images for a fast and accurate measurement of isocenter position. RIT’s version of this test allows you to use 3 to 16 images, and provides error estimates for ball setup and wobble around isocenter. Increased angle flexibility allows you to mimic more clinically relevant angles to determine isocenter at specific treatment configurations. *US Patent 9192784, JP Patent 6009705, CA Patent 2918045, and other international patents pending.
- Stereotactic Alignment (2D Winston-Lutz) Test
- Stereotactic Cone Profiles
- Field Alignment

Beam Measurements
- Radiation/Light Field Coincidence
EPID images may be analyzed without a calibration file and with custom field sizes. Center location can be found by taking a
BB, pinprick, or using an L-Rad Phantom.
- Fully-Automated Star Shot Analysis
- Asymmetric Field/Matchline
- Depth Dose, Cross, and Orthogonal Profiles
- Electron Energy (TG-25)
- Image Histogram
- Isodose Contours
- 3D Dose Profile
- Quick Flatness and Symmetry
- Water Tank Beam Measurement Analysis
- Import TomoTherapy® Calibration Files
TomoTherapy® is a registered trademark of Accuray, Inc.
MLC QA
Varian LINAC
- EPID Picket Fence Test
This routine automates the classic picket fence test.
- Automated Varian RapidArc® Tests
Images may be taken at any distance from EPID, Film, or CR Images. This includes: Tests 0.1, 0.2, 1.1, 1.2, 2, and 3. RIT’s RapidArc QA routines support the Millennium 120, HD120 MLC, and Halcyon® MLC models.
- Varian Leaf Speed Test
Without the use of log files, this test measures the consistency and accuracy of Varian MLC leaf speeds as they move across an imager.
- Varian Halcyon® MLC Analysis
Perform a picket fence or comprehensive RapidArc® analysis of the Halcyon® MLC.
Elekta LINAC
- Hancock Tests for Elekta Machines
The Hancock Tests (2-Image Test, 4-Image Test, and With Backup Jaw Test) use the Elekta iView™ imager to automatically measure leaf position vs. isocenter position, and jaw leaf setback measurements.
- EPID Picket Fence Test
This routine automates the classic picket fence test.
- Elekta Leaf Speed Test
This test aligns two images to analyze the consistency of the leaf speed for both Elekta iView™ and Agility™.
Other MLC Tests
- Bayouth MLC Analysis
Analyze MLCs that require leaf gaps between banks.
- Additional MLC Tests
These include: TG-50 Picket Fence Test, MSK Leaf Test, Varian DMLC Test Patterns, and MLC Transmission analysis.
iView™ and Agility™ are trademarks of Elekta AB. RapidArc® and Halcyon® are registered trademarks of Varian Medical Systems, Inc.
Imaging QA
EPID QC Module
- RIT EPID
(EPID QA Phantom - manufactured and sold by Standard Imaging.) These tests include: constancy in 5 areas, resolution (MTF), geometric distortion, uniformity, contrast, and noise.
- PTW EPID
- Las Vegas EPID
- Standard Imaging QC-3
CATPHAN®, kV and Cone Beam Module
- Varian 504 CATPHAN
- Varian 604 CATPHAN
- Elekta 503 CATPHAN
- Siemens Image Quality Phantom
DR/CR kV Module
- IBA Primus® L
- PTW NORMI® 4
(20x20cm and 30x30cm)
- Leeds TOR-18 FG
- Standard Imaging QC-kV1
kV/MV Module
- Standard Imaging ISOCube
- Penta-Guide
Base Module
- DICOM Image Viewer
- DICOM Tag Viewer
- Image Import: DICOM Directory Browser, Open Directory Browser, DICOM File Filter
- Manual measurements: distance, angle, profile, histograms, round and square ROI, and ASCII output of profiles
- Output formats: Print, PDF export, Excel export with custom templates
- Monitor Image Quality
- Image transfer
Custom Tolerance Management
Use the Tolerance Manager to set tolerance values and pass/fail criteria for every measurement used in all automated phantom analyses. This tool provides the flexibility necessary to customize tolerances on a wide array of LINACs and imaging systems:
- Conveniently set and toggle between tolerances in an easy-to-use panel, located in the main interface, and displayed in every phantom analysis routine.
- Set your own PASS/FAIL criteria for analyses and their corresponding reports, allowing for complete customization in all imaging QA analyses.
- Preference profiles and tolerances are set on a per-machine basis. They can be precisely-tailored to each individual machine in use.
- Transfer all PASS/FAIL tolerance data to the RITtrend™ database for statistical tracking and trending.
Other Measurements
Film Dosimetry for QA
- Radiochromic and Radiochromic Film with Vidar and Flatbed Scanners
- Flatbed Non-Uniformity Correction
- Radiochromic Film Uniformity Correction
- 2D Scanner Spatial Calibration for Vidar and Flatbed Scanners
- Generic Image File Import
- Vidar Scanner Interface (Vidar Scanner Control Center)
Calibration
- MLC Calibration Technique
Patents: EP 1318857, CA 2418232, JP 3817176, US 6675116, US 6934653, and US 7013228.
- 2D Scanner Spatial Calibration for Vidar and Flatbed Scanners
- Perpendicular Dose Calibration
- Calibration File Merge
EPID QA
- Import EPID Images for QA
- Scale DICOM Images from Varian EPIDs
General Features
- Image Compositor
- DICOM Anonymizer
- Pin Prick, Erase, and ROI Tools
- PDF reports for every analysis routine
- Cloud-based software licensing